Skip to content

High potential near miss: dropped object – spark arrestor

What happened?

An 18kg spark arrestor fell 16 metres from the funnel stack and landed on the FRC deck. No-one was injured but this was considered a serious near miss. The spark arrestor was installed at the direction of the charterer only days before the incident. It was installed by a third-party sub-contractor; it was a requirement for working in the field and was new to the vessel.

What went wrong?

  • The spark arrestor became dislodged due to exhaust pressure and vibration;
  • The clamp was not secured tightly enough;
  • The mechanism of securing was pop rivets;
  • Vessel management did not manage the quality control of the third-party work when the spark arrestor was installed.

What were the causes?

  • A causal factor was:
    • installation (fixing) of the spark arrestor was not adequate or to industry standards and not quality checked by the vessel crew or management;
  • Root causes were:
    • failure of vessel operator to conduct a management of change (MoC) process for spark arrestor being installed
    • the vessel operator did not follow contractor management procedures as the third-party installer was not contracted by the vessel.

What lessons were learnt?

  • There should be a management of change (MoC) process applied to all significant modifications or additions to vessel plant and equipment. This should include quality control to verify installation meets industry standards;
  • Contractor management principles still apply even if there is no actual contractual relationship between the vessel operator and the third party doing the work.

What actions were taken?

  • Review and update of safety management system (SMS) documentation (management of change (MoC) and Contractor Management processes) to ensure this scenario involving third parties is properly dealt with;
  • Additional MoC training provided to vessel management teams.

Members may wish to refer to:

Members may also wish to refer to the following incidents:

Safety Event

Published: 20 February 2018
Download: IMCA SF 04/18

Relevant life-saving rules:
IMCA Safety Flashes
Submit a Report

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.

IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.

IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.