Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the the-events-calendar domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/storm/sites/dev-imca-int-com-1/public/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the broken-link-checker domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/storm/sites/dev-imca-int-com-1/public/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the woocommerce-eu-vat-number domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/storm/sites/dev-imca-int-com-1/public/wp-includes/functions.php on line 6114
Lost time injury (LTI): Finger injury during main engine exhaust valve overhaul - DEV imca
Skip to content

Lost time injury (LTI): Finger injury during main engine exhaust valve overhaul

What happened

An engineer suffered a crushed finger when there was an unplanned movement of a main engine exhaust valve during maintenance. The second engineer and a fitter were working together on the overhaul of a main engine exhaust valve. After completion, the valve was tested with compressed air. Once the air was shut off and the seat descended, the second engineer noticed some dirt on the face of the seat. He instructed the fitter to stand clear using hand signals, and attempted to clean the dirt with a rag. At that moment, the fitter opened the air and the seat face moved upwards, crushing the second engineer’s finger as he attempted to remove his hand.

The vessel had to deviate from its course to the nearest port to disembark the injured person for further treatment ashore, to substantial cost. The engineer suffered an LTI and loss of his fingertip.

A risk assessment had been reviewed and a toolbox talk had been carried out prior to the overhaul. It was not clear that communication with hand signals had been discussed at this stage. In the preceding weeks, the same team had undertaken overhaul of three similar exhaust valves.

What went wrong?

  • Some of the immediate causes were found to be:
    • Poor communication – although in plain sight of each other the noise of the engine room meant that verbal communication was not possible between the second engineer and the fitter. The fitter didn’t see or understand the hand signals from the second engineer, and the reopening of the valve was not communicated to the second engineer
    • Hand placed in dangerous position ‘in the line of fire’
    • Following the successful test of the overhauled valve, the compressed air was not disconnected prior to second engineer cleaning the face – crew were servicing equipment that was still in operation
    • Inadequate planning – there was a failure to disconnect the compressed air prior to cleaning the face
    • Hazardous environmental condition – noisy engine room;
  • The root causes were found to be:
    • There was no adequate system of communication and confirmation during operations in noisy environment was not identified during risk assessment neither discussed in the toolbox talk
    • There was no isolation (lockout/tagout)
    • Inadequate compliance – the risk in this routine, recurring task was seen as tolerable.

Lessons learnt/actions taken

  • Develop method of communications in noisy work environment and ensure this is included in risk assessment;
  • Review/familiarisation of crew on company lockout/tagout procedures.

Members may wish to refer to the following similar incidents. (All are similar to the above though not identical. Poor planning and risk assessment, inadequate communications and inadequate procedures, and hand positioning, have led in all these cases to serious hand injuries.)

Safety Event

Published: 1 November 2017
Download: IMCA SF 28/17

Relevant life-saving rules:
IMCA Safety Flashes
Submit a Report

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding safetyreports@imca-int.com to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.

IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.

IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.