Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the woocommerce-eu-vat-number domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/storm/sites/dev-imca-int-com-1/public/wp-includes/functions.php on line 6114
Pilot ladder safety - DEV imca
Skip to content

Pilot ladder safety

The Oil Companies International Marine Forum (OCIMF) has circulated the following safety flash, regarding pilot ladder safety:

Incident 1 – Pilot Ladders

An inspector was boarding a 1.5 year old ship via a pilot ladder, used in combination with the accommodation ladder. As the inspector was half way up the ladder, one of the side ropes parted leaving the inspector on the ladder with only one rope. Fortunately, the other side rope held and the inspector went back down to the launch and boarded the ship after a new ladder was deployed.

Upon boarding the ship, the inspector checked the damaged ladder and reported that, while the ladder generally appeared to be in good condition, the rope had parted at the upper end where an eye was formed around a thimble to allow for securing the ladder.

The rope around the thimble was covered with (heat shrunk) plastic, which did not allow that part of the rope to be inspected before use.

As it turned out, the rope under the plastic covering was completely rotten.

Incident 2 – A near miss with Embarkation Ladders

A near miss report on a ship outlined that, as part of the safety routines on board, the master inspected the ship’s lifeboat embarkation ladders, and noted that the thimble eye by which the ladder secured to the deck had been covered in heat shrunk plastic.

The Master did not approve of this, and asked for these coverings to be removed and the rope inspected.

The covering was removed and, upon inspection, it was noted that the rope was rotten underneath.

Considering that the rope was only about two years old, this deterioration would not have been noted, nor expected, and could have resulted in a serious accident or fatality with worse consequences if the ladder were to be used in an emergency.

These incidents highlight the importance of regularly inspecting every part of all ropes that are deployed on board, whether for safety equipment or for mooring operations.

Plastic covering under which the rope was rotten
Plastic covering under which the rope was rotten

Safety Event

Published: 29 November 2013
Download: IMCA SF 17/13

IMCA Safety Flashes
Submit a Report

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding safetyreports@imca-int.com to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.

IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.

IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.