Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the woocommerce-eu-vat-number domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/storm/sites/dev-imca-int-com-1/public/wp-includes/functions.php on line 6114
Pilot ladder requirements - DEV imca
Skip to content

Pilot ladder requirements

A member has reported an incident in which a vessel was supplied with a new pilot ladder which did not meet International Maritime Organization (IMO) or International Organization for Standardization (ISO) standard. This substandard pilot ladder was noticed by a Pilot in an Australian port. He brought the matter up with the Master via the agent.

Showing knots in the steps (circled)
Showing knots in the steps (circled)

Members are reminded to ensure that:

  • The technical specification of pilot ladders meets IMO requirements as per Resolution A.1045(27);
  • Persons ordering or sourcing new pilot ladders should clearly know the IMO requirements and should specify to suppliers that every step on the ladder should be free of knots;
  • New pilot ladders are thoroughly checked before use to verify quality and to ensure that the steps are clear from knots;
  • Pilot ladders are always checked by the officer in charge before rigging and use to ensure it is fit for purpose, in good condition and secured properly to the vessel.

Please see the following documents:

Members may wish to refer to the following incidents: (search words: pilot, ladder):

Safety Event

Published: 28 March 2017
Download: IMCA SF 07/17

Relevant life-saving rules:
IMCA Safety Flashes
Submit a Report

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding safetyreports@imca-int.com to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.

IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.

IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.