Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the woocommerce-eu-vat-number domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/storm/sites/dev-imca-int-com-1/public/wp-includes/functions.php on line 6114
OCIMF: Pilot ladder side rope failure: Unsafe pilot transfer - DEV imca
Skip to content

OCIMF: Pilot ladder side rope failure: Unsafe pilot transfer

What happened?

During the disembarkation of two pilots from a condensate tanker, the right anterior side rope of a pilot ladder failed. The structural durability of the ladder was visually assessed by the first pilot and determined to be satisfactory; the second pilot managed to disembark without incident. Further inspection of the ladder revealed a parted side rope, which affected the overall stability of the ladder.

Whilst an incident did not occur this time, the failure of the side rope did in fact create an unsafe condition for pilot transfer, therefore creating a high potential hazard.

What went wrong?

  • The pilot ladder side rope had been weakened due to mould;
  • Inspections that were in place were ineffective.

What actions were taken? What lessons were learned?

  • A close visual inspection by trained personnel could have noticed the damage;
  • Improvement needs to be made to the ladder inspection processes;
  • Update knowledge on finding faults with pilot ladders and rope damage;
  • Change the pilot transfer procedure and review alternative methods.

Members may wish to refer to the following incidents:

Safety Event

Published: 30 October 2018
Download: IMCA SF 24/18

Relevant life-saving rules:
IMCA Safety Flashes
Submit a Report

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding safetyreports@imca-int.com to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.

IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.

IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.