Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the the-events-calendar domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/storm/sites/dev-imca-int-com-1/public/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the woocommerce-eu-vat-number domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/storm/sites/dev-imca-int-com-1/public/wp-includes/functions.php on line 6114
Near-miss: Open hatches left without barriers - DEV imca
Skip to content

Near-miss: Open hatches left without barriers

A member has reported a near miss incident in which a number of hatches on deck were left open without any form of barrier, creating the potential for injury if persons were to fall down the hatches. The incident occurred during ‘routine’ tank cleaning operations carried out by an authorized tank cleaning contractor on board a supply vessel. During night shift vessel inspection and tank cleaning operation monitoring, 10 tank hatches were observed open and left uncontrolled (potential to fall into the manhole for some employees working near the open hatches).

Initial investigation revealed that 11 diesel tank hatches were opened and gas tested; the 10 hatches were left open for ventilation without any protection/control measures or any barriers for each hatch. The overall area was barricaded off by tape by the tank cleaning contractor with a single standby person allocated on deck.

Our member noted the following:

  • 10 hatches were left open for ventilation without any barriers;
  • There were no additional control measures in place, except a verbal caution during the toolbox talk about the risk of falling into the open hatches;
  • The unsafe condition was neither identified nor challenged by any personnel from the contractor or from the vessel crew.

Our member took the following actions:

  • Tank cleaning operations were stopped for the moment;
  • A safety stand-down was conducted with emphasis on the potential hazards and the requirement to be vigilant and initiate a stop work authority for any unsafe conditions identified;
  • Further thorough review of task risk assessment and procedures for tank cleaning and other dangerous space entry activities – with consideration of better management of the open hatches;
  • Further clarification of roles and responsibilities during simultaneous operations (SIMOPS) and during tank cleaning;
  • Barriers and vented grating ordered for all vessels in fleet.

Safety Event

Published: 12 October 2016
Download: IMCA SF 27/16

IMCA Safety Flashes
Submit a Report

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding safetyreports@imca-int.com to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.

IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.

IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.