Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the woocommerce-eu-vat-number domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/storm/sites/dev-imca-int-com-1/public/wp-includes/functions.php on line 6114
MAIB: fatal man overboard incident whilst boarding tug - DEV imca
Skip to content

MAIB: fatal man overboard incident whilst boarding tug

What happened?

The UK Marine Accident Investigation Branch (MAIB) has published Accident Investigation Report 15/2019 into a fatality whereby a man fell overboard whilst boarding a tug at an oil terminal at Birkenhead, England.

At 1749 on 27 January 2019, the chief engineer on-board the tug Millgarth, fell into the water from the North oil stage at the Tranmere Oil Terminal at Birkenhead, England.  He had released Millgarth‘s mooring lines and was attempting to re-board the tug.  His lifejacket inflated automatically on entering the water and his crewmates were able to recover him alongside the tug within 5 minutes.  The crew were unable to lift the chief engineer out of the water because he had quickly become incapacitated in the cold water and lost consciousness.  He was recovered at 1811 by the crew of rescue boat Marine Fire Rescue 1; he had suffered cardiac arrest and could not be revived.

What went wrong?

The MAIB notes:

  • Accessing the tugs via the oil stage fenders at the Tranmere Oil Terminal was a common practice and was extremely dangerous, particularly in poor weather conditions;
  • The lack of safe access to and from Svitzer tugs at Tranmere Oil Terminal had been recognised for at least 14 years prior to this accident and had been raised at safety committee meetings and during company inspections many times prior to this accident;
  • Svitzer UK and Essar did not formally identify and evaluate the shared risks associated with access to and from an unmoored tug or discuss how these could be mitigated;
  • The crew had not been fully prepared to deal with the emergency situation and were unfamiliar with the use of the tug’s MOB rescue-sling

Recommendations

  • On 14 June 2019, the MAIB carried out a preliminary assessment of a non-fatal man overboard incident on Svitzer Victory. Due to the similarity of this incident with the fatal accident on Millgarth, the Chief Inspector of the MAIB issued an urgent safety recommendation (2019/115) to Svitzer A/S concerning the safe conduct of tug access and egress;
  • This report makes further safety recommendations (2019/121 and 2019/122) to Svitzer A/S regarding the dissemination and closure of audit findings, attendance at man overboard drills and the use of man overboard recovery equipment.

Members may wish to refer to MAIB report 19/2016: fatal accident while manoeuvring Svitzer Moira alongside an unmanned tug Royal Portbury Dock, Bristol on 29 December 2015.

Members may wish to refer to:

Safety Event

Published: 30 January 2020
Download: IMCA SF 03/20

Relevant life-saving rules:
IMCA Safety Flashes
Submit a Report

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding safetyreports@imca-int.com to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.

IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.

IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.