Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the woocommerce-eu-vat-number domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/storm/sites/dev-imca-int-com-1/public/wp-includes/functions.php on line 6114
Failure of bail-out regulator - DEV imca
Skip to content

Failure of bail-out regulator

During routine maintenance of bail-out bottles on a member’s dive support vessel (DSV), a serious flaw was discovered on a first stage bail-out regulator. When the relief valve was dismantled, it was found that two mild steel washers had been fitted to the valve to effectively increase the spring tension to allow for a 20 bar pressure release. Both washers were badly corroded and prevented operation of the relief valve.

In a situation where a regulator fails because the relief valve is inoperable, there is potential for the low pressure (LP) hose to be subjected to full bail-out pressure of 300 bar. New-type LP hoses have a working pressure in excess of 60 bar but, because of safety factors, will have a considerably higher burst pressure. Thus there is potential to have full bailout pressure at the helmet emergency valve without the diver’s knowledge.

When the history of the first stage regulator’s relief valve was investigated, the company involved could not trace when they had been delivered. The manufacturer had no knowledge of such washers ever being fitted to its relief valves, as the normal relief valve setting from the manufacturer was 15 bar. It is understood that that supplier manufactures special relief valve caps to allow for a 20 bar pressure relief, but this was based on different spring settings. The company’s maintenance procedures would prohibit such materials being inserted in the regulator valves and documentary evidence of when this occurred could not be found.

The company involved is concerned that this may not be an isolated case of incorrect supply or maintenance and has instructed all of its diving supervisors to check all first stage regulators at the earliest opportunity to confirm that the relief valves have the correct components fitted, in accordance with suppliers’ specifications. This check was to include both units in use and stored standby units.

Safety Event

Published: 1 September 2002
Download: IMCA SF 09/02

IMCA Safety Flashes
Submit a Report

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding safetyreports@imca-int.com to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.

IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.

IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.