Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the woocommerce-eu-vat-number domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/storm/sites/dev-imca-int-com-1/public/wp-includes/functions.php on line 6114
Explosion and fire on-board the chemical tanker Stolt Groenland - DEV imca
Skip to content

Explosion and fire on-board the chemical tanker Stolt Groenland

What happened?

The UK Marine Accident Investigation Branch (MAIB) has published its interim report into a serious explosion and fire on-board the chemical tanker Stolt Groenland on 28 September 2019 at Ulsan in South Korea.  The incident occurred during ship-to-ship transfer of highly flammable styrene monomer, one of 20 different chemical cargoes the vessel was carrying in 37 of its 39 cargo tanks.

At 1043, vapour started to release from a pressure vacuum valve for the tank which contained styrene monomer.  About two minutes later, a high-level alarm indicated that the level in the tank had reached 95%, soon followed by a ‘high-high’ level alarm indicating that the level had increased to 98%.  By now, Stolt Groenland‘s on-watch deck officer and chief officer had made their way to the cargo control room.

At 1050, two explosions were seen and heard in rapid succession in way of the tanker’s cargo manifold.  The resulting fireball passed very close to a road bridge above the quay.

The fire was fought from the shore and from the water and lasted until the early hours of the following morning.  There was extensive damage to the vessel and a number of crew and firefighters were injured.

What went wrong?

The MAIB’s initial findings were that the explosions were probably caused by the rupture of the deck above the cargo tank, followed immediately by the ignition of the styrene monomer vapour that was then released.  The rupture was due to over-pressurisation and the likely sources of the ignition were static electricity, sparks or elevated steel deck plate temperatures resulting from the tank rupture. 

The full interim report can be found here.

Members may wish to refer to:

Safety Event

Published: 30 January 2020
Download: IMCA SF 03/20

IMCA Safety Flashes
Submit a Report

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding safetyreports@imca-int.com to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.

IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.

IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.