Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the the-events-calendar domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/storm/sites/dev-imca-int-com-1/public/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the broken-link-checker domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/storm/sites/dev-imca-int-com-1/public/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the woocommerce-eu-vat-number domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/storm/sites/dev-imca-int-com-1/public/wp-includes/functions.php on line 6114
Safety Events Archive - Page 58 of 82 - DEV imca
Skip to content

IMCA safety flashes disseminate important information on incidents and potential hazards and the lessons learnt from them that can help prevent incidents occurring elsewhere in the industry.

Individual safety events are available individually online, tagged and searchable, while the traditional PDF collections are also available for download.

Submit a Report

All members are encouraged to contribute relevant safety-related information – please visit our Safety Flash Reporting page for details on the submission process.

IMCA Contact

Nicholas Hough
Technical Adviser - HSSE and Offshore Survey
Contact

Select some filters

Injury during personnel transfer capsule operation

A member has reported an incident in which a person was injured during a personnel transfer capsule operation. Three persons involved in pipeline commissioning activities on a recently installed jacket […]

| Included in IMCA Safety Flash 17/09

Near-miss: ROV fuse bolt failure

A member has reported an incident in which a crew member was narrowly missed by the head of a fuse bolt which had been shot out of a remotely operated […]

| Included in IMCA Safety Flash 16/09

Bell bottom door hydraulic operating system failure

A member has reported the failure of a bell bottom door hydraulic operating system. The failure occurred while carrying out standard bell recovery operations using the port dive bell on […]

| Included in IMCA Safety Flash 16/09

Tumble dryer fire onboard a vessel

A member has reported an incident in which there was a small fire inside the drum of a tumble dryer on a vessel offshore. A burning smell was detected on […]

| Included in IMCA Safety Flash 16/09

Hand injury: Injection of hydraulic fluid

IMCA has received information about a hand injury caused by leaking pressurised hydraulic fluid on a drilling rig. A person was searching for the source of a small hydraulic leak. […]

| Included in IMCA Safety Flash 16/09


Near-miss: Unexpected lowering of a suspended load

A member has reported an incident in which there was an unexpected lowering of a suspended load during a lifting operation which had the potential to cause significant injury. During […]

| Included in IMCA Safety Flash 16/09

Importance of inspecting fall protection equipment

IMCA has been made aware of a number of examples of fall protection equipment failing owing to poor or sub-standard equipment: Safety Alert 09-17 – Near Miss – New Fall […]

| Included in IMCA Safety Flash 15/09


Lost time injury (LTI): Gangway deployment

A member has reported an incident in which a person suffered a broken leg during gangway deployment. Prior to arrival at the quayside, a vessel’s double sectioned gangway (see Figure […]

| Included in IMCA Safety Flash 15/09

Trapped diver umbilical incident resulting in diver fatality

A member has reported an incident where a trapped diver umbilical resulted in his death. During the surface supplied diver operation, the diver was deployed to the bottom (56m) to […]

| Included in IMCA Safety Flash 15/09

Potential threat to aviation posed by Skysails

We have received two safety alerts – from CHC Helicopter and the European Organisation for Safety of Air Navigation (Eurocontrol) – concerning a recent incident involving a Skysail, an experimental […]

| Included in IMCA Safety Flash 14/09

Torn ankle ligaments

The Marine Safety Forum has published the attached safety flash (09/30)concerning a crew member injured whilst stepping from one vessel to another when no gangway was available.

| Included in IMCA Safety Flash 14/09

Failure of gas supply to diving bell

A member has reported an incident in which there was a failure of the breathing system in a diving bell. During diving operations at a storage depth of 102 metres, […]

| Included in IMCA Safety Flash 14/09

Use of pre-mixed nitrox gases

An incident has been brought to IMCA’s attention where premixed cylinders or quads of nitrox gas may not have had the necessary oxygen content to sustain safe diving and the […]

| Included in IMCA Safety Flash 13/09

Lift bag lost when rigging parted

A member has reported an incident in which a lift bag was released to surface upon parting of the rigging attachment point straps. The lift bag was of the open […]

| Included in IMCA Safety Flash 12/09

Dropped object near-miss

A member has reported an incident in which an object was dropped whilst being lowered to divers on the seabed. The vessel was working in waters over 100m depth when […]

| Included in IMCA Safety Flash 12/09

Pillar valve failure

A member has reported an incident in which a pillar valve from an emergency gas cylinder separated from the bottle while under pressure, rapidly releasing 50 cu ft of air […]

| Included in IMCA Safety Flash 12/09

Falling object – struck by crane stop/striker plate

A member has reported an incident in which workers were struck by a falling crane stop/striker plate, causing injuries. Two third-party contractors were carrying out non-destructive testing (NDT), lubrication and […]

| Included in IMCA Safety Flash 11/09

Uncontrolled movement of A-frame

A member has reported an incident in which there was an uncontrolled movement of an A-frame mechanism. The uncontrolled movement of the A-frame luffing function occurred whilst personnel were working […]

| Included in IMCA Safety Flash 10/09

1637 post(s)