Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the the-events-calendar domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/storm/sites/dev-imca-int-com-1/public/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the broken-link-checker domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/storm/sites/dev-imca-int-com-1/public/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the woocommerce-eu-vat-number domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/storm/sites/dev-imca-int-com-1/public/wp-includes/functions.php on line 6114
Near miss: unplanned deployment of PLET outrigger - DEV imca
Skip to content

Near miss: unplanned deployment of PLET outrigger

What happened?

As a pipeline end termination (PLET) passed through the firing line, a rigger incorrectly cut a webbed ratchet strap (instead of a 6mm rope lanyard) which was restraining the aft PLET outriggers/stabilizer legs in the upright position. After cutting the ratchet strap, the starboard stabilizer leg deployed to approximately 35 degrees from vertical, coming to rest on the pipeline induction heat (PIH), injection moulded poly propylene (IMPP) unit. The port side outrigger released (approximately 60 degrees from vertical) until it came to rest on a nearby handrail.

What went wrong? What were the causes?

  • Engineering design: there was no integral mechanical means to lock or hold the outriggers in the vertical position;
  • Management of change (MoC): original drawings indicated a wire rope sling arrangement which was later changed to a flat ratchet strap;
  • A risk assessment did not identify the potential stored energy hazard posed by the outriggers;
  • Communication: a decision was made to introduce 6mm rope to the ratchet strap to allow for easy retrieval subsea with an ROV. This decision was made informally and intermittently conveyed between teams (field engineers and rigging), which introduced a new risk.

What actions were taken? What lessons were learned?

  • Reviewed risk management process for the design of subsea structures to make the process more robust and to allow the project team to analyse structure designs and address all failure points during the design phase;
  • Ensure changes to designs as supplied by a customer are managed robustly with justification documented for any engineered changes in rigging arrangements – a more robust MoC;
  • Thorough review of risk management processes, particularly between teams and in the ‘interface’ between teams; in this case, between the fabrication and project teams;
  • Reinforced the importance of clear communication during critical operations, to ensure the message/work scope is delivered in a clear manner and that any risks are fully understood by the crews.

Safety Event

Published: 9 November 2018
Download: IMCA SF 25/18

Relevant life-saving rules:
IMCA Safety Flashes
Submit a Report

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding safetyreports@imca-int.com to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.

IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.

IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.