Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the the-events-calendar domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/storm/sites/dev-imca-int-com-1/public/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the broken-link-checker domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/storm/sites/dev-imca-int-com-1/public/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the woocommerce-eu-vat-number domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/storm/sites/dev-imca-int-com-1/public/wp-includes/functions.php on line 6114
Lifeboat davit failure - DEV imca
Skip to content

Lifeboat davit failure

Following a refit, sea trials were being conducted on a member’s vessel in preparation for a return to operations. Defects were discovered on the davit tilt arms on both the forward and aft legs of two lifeboat davits. Both tilt plates on each leg of the aft davits were found to be cracked and distorted. It was evident after inspection that the initial defects were historical and may have existed for some time unnoticed. The defects may have been compounded by load tests conducted during the recent refit, during which the davits had been upgraded to allow new lifeboats to be installed.

Following further investigation with the close co-operation of the original equipment manufacturer it was concluded that the defects to the davit tilt arms were caused by the incorrect operation of the davits. The davit arms had previously been brought inboard of the vessel without the required minimum 500kg weights attached to the davit hooks. A clear warning that this should not take place is included in this specific manufacturer’s documentation.

The following actions were recommended:

  • The original equipment manufacturer’s documentation for the davits should be consulted and appropriate operating instructions verified to ensure existing practices do not deviate from manufacturer-recommended launching practices, nor compromise the safety and operational integrity of the equipment;
  • Davit launch/recovery operators should ensure that the davit is operated in accordance with the guidance provided by the original equipment manufacturer;
  • Warning notices should be posted adjacent to each lifeboat operating station (see the diagram below);
  • A thorough inspection of tilt plates should be included in monthly planned maintenance checks;
  • Since the defects appear to have originated some time in the past, better quality control is required of bi-annual, annual and five-yearly inspections by specialist contractors to ensure that they are conducting the thorough examination of the equipment properly and to an appropriately high standard.
Suggested warning placard to be placed near lifeboat operating station
Suggested warning placard to be placed near lifeboat operating station
Worn davit tilt plate and parts
Worn davit tilt plate and parts
Worn davit tilt plate and parts
Worn davit tilt plate and parts
Lifeboat davit
Lifeboat davit

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding safetyreports@imca-int.com to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.

IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.

IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.