Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the the-events-calendar domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/storm/sites/dev-imca-int-com-1/public/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the broken-link-checker domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/storm/sites/dev-imca-int-com-1/public/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the woocommerce-eu-vat-number domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/storm/sites/dev-imca-int-com-1/public/wp-includes/functions.php on line 6114
Clarification from NOPSEMA: Quality assurance of diving system audits - DEV imca
Skip to content

Clarification from NOPSEMA: Quality assurance of diving system audits

The National Offshore Petroleum Safety and Environmental Management Authority (NOPSEMA) of Australia published Safety Alert 63 regarding the quality assurance of diving system audits. 

This was passed on to IMCA members as IMCA safety flash 03/17, incident 2 – Quality assurance of diving system audits.  Additional information drawn to the attention of NOPSEMA has made some changes necessary.  The alert has now been re-issued as Safety Alert 63 Rev. 1.

“A number of NOPSEMA inspections have identified a trend in the standard of audits conducted on diving systems and equipment.  Specifically, a number of operators of diving projects and diving contractors have failed to ensure diving system audits have been conducted to an appropriate standard.  While reviewing the audits conducted by the diving project operators and the diving contractors, NOPSEMA’s inspectors identified the following deficiencies:

  • Man-riding wire destructive test certification was not adequately assessed, resulting in the failure to identify that the percentage deterioration was greater than that permitted by the relevant International Marine Contractor’s Association (IMCA) code/guidelines and therefore should have been replaced;
  • Inappropriate application of a management of change process to justify the deferral of man-riding wire destructive tests;
  • Failure to make an emergency services umbilical available for SPHL connection to its life support package;
  • A high pressure (200 bar) flexible oxygen hose was found during a NOPSEMA inspection to be too long, made up with joins and was damaged, however it was marked as compliant during an earlier audit;
  • Older diving systems built to class have not been upgraded, where practicable, to meet current class requirements e.g. fire suppression systems within diving chambers unable to be externally actuated.

Each of the deficiencies outlined above should have been identified and rectified as a result of the third party or in-house audits.”

NOPSEMA notes that: “Failure to identify audit non-conformances associated with safety-critical elements of a diving system may result in an increased level of risk to the air and saturation divers.  The non-conformance examples provided above have the potential to compromise the integrity of the system components and reduce functionality in an emergency.  Any loss of integrity or system redundancy has the potential to result in serious injury or fatalities to divers and others involved in diving operations.”


IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding safetyreports@imca-int.com to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.

IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.

IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.