Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the the-events-calendar domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/storm/sites/dev-imca-int-com-1/public/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the broken-link-checker domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/storm/sites/dev-imca-int-com-1/public/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the woocommerce-eu-vat-number domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/storm/sites/dev-imca-int-com-1/public/wp-includes/functions.php on line 6114
Dropped object: Failure of lump hammer - DEV imca
Skip to content

Dropped object: Failure of lump hammer

A member has reported an incident in which a wooden hammer shaft failed and the head fell to deck. Two personnel were located at the upper main tensioner level of a pipelay tower, removing dowels from the tensioner gear boxes using a spanner wrench, dowel removal tool and the 2kg lump hammer. During this process the personnel were striking the spanner wrench with the lump hammer. On a downward swing of the hammer and at impact with the spanner wrench, the hammer head detached from the shaft and fell approximately 25 meters vertically through the tensioner to the deck below. There were no injuries. Had the falling hammer head struck a person, according to the DROPS calculator it would have caused a fatality.

The purpose of this safety flash is to highlight the hazards of using tools at height which are not specifically designed for use at height, and to reiterate the importance of preventive measures to eliminate the risk of dropped objects.

Pipelay tower showing where hammer fell
Pipelay tower showing where hammer fell
Broken lump hammer
Broken lump hammer

Our member’s investigation noted the following:

  • This particular brand of hammer had been ordered in 2011 following a similar incident in which a wooden hammer shaft failed and the head fell to deck. These hammers were deemed suitable for use at height at that time due to the design of the wedging system for the hammer head giving a high degree of securing. This particular hammer had been stored on the vessel and brought into service six months prior to the incident;
  • The area below had been barriered off and sentries were posted to prevent personnel entering the area;
  • The hammer appeared to be sound and the head was not loose prior to use;
  • The hammer was not specifically designed for use at height, and the head can (and did) separate from the shaft;
  • The reason for the failure was not yet known, the manufacturer claimed to have a design that requires 20% more force to pull the head from the handle than a conventional wedged hammer, but it had nevertheless failed whilst in use;
  • Despite inspection prior to use, the hammer showed no defects. A specifically designed hammer for working at height such as from Stop-Drop Tooling, would not have failed in this way as the head cannot come free from the shaft;
  • The shaft of the hammer was fitted with a lanyard, there was however no way to prevent the head dropping with this type of hammer.

Our member took the following actions:

  • Ensured that this particular brand of hammer was NOT used at height subsequently;
  • Supervisors to ensure that tools used for working at height offer complete dropped object prevention, and liaise with their Health & Safety Executive (HSE) Superintendent for advice if new tools are required; . Continued liaison with hammer manufacturer regarding the failure.

Further information on safe working at heights can be found in the following IMCA safety promotional material:

Members may wish to refer to the following similar incidents (key words: dropped, tool, hammer):

Safety Event

Published: 5 February 2015
Download: IMCA SF 02/15

IMCA Safety Flashes
Submit a Report

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding safetyreports@imca-int.com to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.

IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.

IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.