Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the the-events-calendar domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/storm/sites/dev-imca-int-com-1/public/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the broken-link-checker domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/storm/sites/dev-imca-int-com-1/public/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the woocommerce-eu-vat-number domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/storm/sites/dev-imca-int-com-1/public/wp-includes/functions.php on line 6114
Hand injury during retrieval of personal protective equipment (PPE) stored inside a compressor unit - DEV imca
Skip to content

Hand injury during retrieval of personal protective equipment (PPE) stored inside a compressor unit

An incident has come to IMCA’s attention in which a crewman suffered a hand injury caused by a slamming door on a compressor unit. The incident occurred when a contractor worker took off his PPE and kept it inside the compressor whilst visiting the lavatory. When he returned and retrieved his PPE from the inside of the compressor unit, a part of the door slammed due to high wind and caught his hand, resulting in an injury to his index finger. The injured person was rushed to hospital where he was received two stitches.

Compressor unit with PPE and flammable materials inappropriately stored inside
Compressor unit with PPE and flammable materials inappropriately stored inside
Compressor unit with PPE and flammable materials inappropriately stored inside
Compressor unit with PPE and flammable materials inappropriately stored inside

Investigation findings noted the following:

  • Using equipment enclosures as temporary storage can potentially lead to harm of people and damage to equipment;
  • The worker placed his PPE inside the compressor unit. The inside of the compressor unit was used by the crew habitually as a storage area for PPE;
  • There were other flammable materials seen stored inside the compressor unit, which could potentially lead to major fire and explosion;
  • The incident was not reported in a timely way;
  • There was no evidence of new risk assessment being conducted prior to recommencing of the work, and PPE was seen being stored inside the compressor unit the following day – the lessons were not learnt by the crew.

The following actions were taken:

  • Ensure all incidents are reported immediately;
  • Ensure no materials are stored inside any operational machinery;
  • Ensure PPEs/other materials are stored in designated area only.

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding safetyreports@imca-int.com to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.

IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.

IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.