Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the the-events-calendar domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/storm/sites/dev-imca-int-com-1/public/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the broken-link-checker domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/storm/sites/dev-imca-int-com-1/public/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the woocommerce-eu-vat-number domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/storm/sites/dev-imca-int-com-1/public/wp-includes/functions.php on line 6114
Lifeboat falls after equipment failure - DEV imca
Skip to content

Lifeboat falls after equipment failure

A member has reported an incident in which equipment failure allowed a lifeboat to fall free from one side of a vessel. The incident occurred during periodical function tests performed on the vessel lifeboats. When the port side lifeboat was recovered, one of the wire rerouting sheaves from the launching/recovery system buckled and broke off allowing the lifeboat to free fall from one side. The lifeboat and launching system were seriously damaged. No personnel were on board the lifeboat at the time, and there were no injuries.

A thorough investigation was conducted and the following was noted:

  • When the incident occurred, one davit arm was in its rest position, while the other one was still under recovery;
  • Severe deformation of the sheaves and their support plate indicated an ‘out of plane’ loading;
  • The sheave had signs of groove wear and corrosion of the bottom side;
  • Though the functioning of the entire lifeboat launch and recovery system was tested periodically, there was no preventive maintenance programme for separate pieces of equipment within the system.

The following remedial actions were put in place:

  • Replaced lifeboat lift wire with particular attention to the length adjustment;
  • Replaced damaged (bent) support plate;
  • Thorough cleaning and removing old paint from boom guide and sheaves, replacing as necessary;
  • Non-destructive testing on pin from sheaves.

It was also noted that owing to the work environment and equipment criticality, a preventative maintenance schedule for individual parts on the lifeboat launch and recovery system should be developed, as this would reduce the likelihood of this type of equipment failure.

Safety Event

Published: 23 December 2011
Download: IMCA SF 14/11

IMCA Safety Flashes
Submit a Report

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding safetyreports@imca-int.com to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.

IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.

IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.