Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the the-events-calendar domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/storm/sites/dev-imca-int-com-1/public/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the broken-link-checker domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/storm/sites/dev-imca-int-com-1/public/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the woocommerce-eu-vat-number domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/storm/sites/dev-imca-int-com-1/public/wp-includes/functions.php on line 6114
Failure of chamber door spindles and seals - DEV imca
Skip to content

Failure of chamber door spindles and seals

A member’s diving support vessel (DSV) had recently completed a period of maintenance with some minor work on the saturation chamber system, which included door hinge realignment.

During pressurisation of the divers, a leak was identified from the lock between the two occupied chambers. Pressurisation was halted at 5 msw and the system surfaced for repair. On completion of the repair the system was again pressurised when a different leak on the same door caused the pressurisation to be halted at 8 msw.

Both leaks were identified as being at the seals in the door spindle shafts that passed through the chamber doors to enable the retaining ‘dogs’ to be operated from both sides of the chamber door. The two leakages prompted an inspection of all the door spindles in the system, identifying the following:

  • There was no history available on the spindles or seals, as they were not part of the planned maintenance system.
  • Almost 70% of the door spindles were found to be unserviceable due to surface damage in the sealing area or bending of the shafts and required replacement.
1. Shaft damage, 2. Shaft surface damage, 3. Door spindles in place in chamber door
1. Shaft damage, 2. Shaft surface damage, 3. Door spindles in place in chamber door

The following points are highlighted to members who have diving systems configured with spindles through chamber doors:

  • The door spindles and associated seals should be identified as critical components.
  • Inspection and replacement of the door spindles and seals should be included in the planned maintenance system.

Safety Event

Published: 14 August 2007
Download: IMCA SF 07/07

IMCA Safety Flashes
Submit a Report

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding safetyreports@imca-int.com to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.

IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.

IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.