Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the the-events-calendar domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/storm/sites/dev-imca-int-com-1/public/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the broken-link-checker domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/storm/sites/dev-imca-int-com-1/public/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the woocommerce-eu-vat-number domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/storm/sites/dev-imca-int-com-1/public/wp-includes/functions.php on line 6114
Line parting as a result of socket failure during grapnel operations - DEV imca
Skip to content

Line parting as a result of socket failure during grapnel operations

A member has reported an incident in which a line parted during grapnel operations. The incident occurred as grapnels were being recovered during attempts to snag, capture and recover a cable on the seabed.

The end of the rope pulled out of its socket, releasing the rope down the aft deck and overboard. A bar at the stern was damaged and a camera and floodlight were carried overboard.

Parted rope on deck
Resulting damage to Atlantic bar

Our member noted the following:

  • Higher than expected tensions were experienced during the recovery. At the time of the incident rope tension was observed to be 175kN;
  • During watch handover, the situation regarding high tensions (averaging 130-140kN) was properly explained;
  • The aft deck and “Snap Back Zones” were kept clear as per normal practice;
  • The “Atlantic bar” was in place on the stern sheave;
  • All ropes had been inspected (as per toolbox talks conducted and recorded) during pay-out and recovery, and there was no sign of excessive degradation to the failed rope or fitting prior to the incident;
  • The recovery of the grapnels at higher than expected tensions, handover and safety briefing in unusual operation conditions, and back deck/snap-back zone safety were all handled diligently and professionally;
  • The rope failed at less than the minimum breaking load (MBL) of the rope, which was 25.0 tonnes:
    • tensions of up to 200kN (app. 20 tonnes) had been experienced during the recovery
    • the working load limit (WLL) of the rope would have been 12.5 tonnes (app. 125kN) which was adequate for the expected tensions (app. 100-120kN / 10-12 tonnes);
  • It is possible that the rope socket had gradually degraded over the previous 10 grapnel drives, but with no obvious visual signs of having done so.

Members may wish to refer to the following incident:

Loss of ROV after umbilical termination failure and damage to ROV during recovery

Safety Event

Published: 12 May 2017
Download: IMCA SF 10/17

Relevant life-saving rules:
IMCA Safety Flashes
Submit a Report

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding safetyreports@imca-int.com to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.

IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.

IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.