Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the the-events-calendar domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/storm/sites/dev-imca-int-com-1/public/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the broken-link-checker domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/storm/sites/dev-imca-int-com-1/public/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the woocommerce-eu-vat-number domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/storm/sites/dev-imca-int-com-1/public/wp-includes/functions.php on line 6114
Lifting wire strop failure during air bag lift - DEV imca
Skip to content

Lifting wire strop failure during air bag lift

A member has reported the following incident, which occurred during a diving operation from a DP diving support vessel. The diver was asked to inflate a 5 tonne air lift bag, which had swaged half inch wire strop passing through the 12 o’clock bolt hole position on tie-in flanges. The lift bag was being used to lift and align flanges in position prior to bolt installation. While filling the lift bag, the diver was asked by the diving supervisor to double-check the attached rigging. The diver reported a sharp bend on the wire strop through the 12 o’clock bolt hole of the flange end which went up to the lift bag. As a precaution, the supervisor instructed the diver to stop inflating the airbag, to deflate and remove the airline.

While he was undoing the airline, which was made cold, the wire strop parted, causing the lift bag and airline to come to the surface around 20 metres from port side of the vessel. The diver was on a clear path to the bell with his umbilical and was far away from the air bag rigging attachment, thus averting possible entanglement. The company notes that this avoided what could potentially have been a fatality. The diver was reported well after the incident.

Inverter ripped out from this location
Inverter ripped out from this location

End of strop cut on flange face
End of strop cut on flange face

On inspection of the air lift bag, it was found that the inverter line attached to the top of the bag had pulled out, resulting in the lift bag failing to spill the air contained and the bag reaching the surface. The diver reported that the bag was only half to two-thirds full in capacity at the time of the incident.

The company identified the following contributory factors:

  • The less-than half inch wire rope strop passing through the flanges and attached to the air lift bag had not been certified;
  • The inverter line pulled out of the top tab (the tab burst) and thus the air bag could not be inverted;
  • The suitability of the rigging had not been thoroughly checked prior to lowering the air bags to the seabed.

The following points were identified as helping avoid an even more serious incident:

  • Timely observation by the supervisor and his instruction to the diver to check the rigging while inflating the lift bag;
  • The diver and his umbilical were out of the ascent path of the air lift bag, thus avoiding what could potentially have become a fatality.

The company has taken the following corrective measures following the incident:

  • The incident was discussed in toolbox meetings and the potential effects were discussed by the diving superintendent and OCM;
  • The dive team has been reminded of the importance of checking all rigging prior to attachment to loads and of following proper lifting procedures;
  • The rigging gear onboard the vessel has been inspected both for any damage and to ensure it is properly certified;
  • The air bag supplier is further investigating the incident.

The company has issued a reminder that lifting incidents, including air bag lifting, carry the potential for serious injuries and fatalities to occur, reiterating the need to follow proper procedures, to review lifts at toolbox meetings before they commence and to keep abreast of company and industry guidance on the subject.

Safety Event

Published: 23 August 2006
Download: IMCA SF 10/06

IMCA Safety Flashes
Submit a Report

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding safetyreports@imca-int.com to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.

IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.

IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.