Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the the-events-calendar domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/storm/sites/dev-imca-int-com-1/public/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the broken-link-checker domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/storm/sites/dev-imca-int-com-1/public/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the woocommerce-eu-vat-number domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/storm/sites/dev-imca-int-com-1/public/wp-includes/functions.php on line 6114
Life raft self-activates and falls to the quayside - DEV imca
Skip to content

Life raft self-activates and falls to the quayside

What happened?

A life raft self-activated and fell from its cradle from the vessel deck, 8m down onto the barriered quayside bollard area. The weather temperature at the time was 44°C.

The life raft securing straps, pennant line and life raft station security belts were inspected, and no signs of external impact observed. Investigation identified that the life raft self-inflated following sudden release of gas from the gas cylinder. Further inspection of the cylinder by a third-party showed no damage or corrosion to the bushing disc or the circular piece cut; internal inspection of the cylinder found no excessive surface corrosion.

There were no personnel injuries, and no property damage.

What were the causes?

  • The gas cylinder was not properly serviced by a third-party service provider;
    • investigation identified that improper torque force was applied to cylinder valve disc bushing
    • the disc was not wound back while the cylinder was being filled. This bent the disc towards the anvil and pushed it hard against it. This could have damaged the disc and then failed as the pressure rises on a hot day
    • potential damage to diaphragm and overfilling of cylinder, added to build-up of pressure due to the extreme heat over a sustained period, could have led to the diaphragm failure.

What lessons were learned?

  • When servicing OEM supplied equipment, manufacturer’s service manual requirements should be complied with at all times;
  • When making use of third-party providers, ensure that there is proper communication and ensure an effective service provision assurance process is implemented.

Members may wish to consider such issues as control of sub-contractors and third parties, in addition to the technical cause here relating to equipment failure in extreme heat.


IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding safetyreports@imca-int.com to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.

IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.

IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.