What happened?

The Norwegian Petroleum Safety Authority (PSA) has completed its investigation of the fatal accident on 7 December 2017 on Maersk Interceptor, a jack-up facility, in which one person was killed and another seriously injured.  Several breaches of the (Norwegian) regulations were identified.

This incident occurred in connection with lifting and installing a seawater pump.  Four people took part in the work, which involved the use of a steel sling.  The latter parted, and the pump fell down.  A power cable attached to the pump was pulled along in the fall and hit two people who were in the vicinity.  One of them fell into the sea and died, while the other was seriously injured.  Under slightly different circumstances, several lives could have been lost.

The incident also had material and financial consequences.

What were the causes?

  • The direct cause of the incident was that the lifting sling broke because it was overloaded;
  • Underlying causes were multiple and complex and can be related to design weaknesses and inadequacies in following these up, failure to identify risk at several levels, training, and planning and work practice.

The full report can be found here.

Safety Event

Published: 21 December 2018
Download: IMCA SF 29/18

Relevant life-saving rules:
IMCA Safety Flashes
Submit a Report

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.

IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.

IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.