Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the the-events-calendar domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/storm/sites/dev-imca-int-com-1/public/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the broken-link-checker domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/storm/sites/dev-imca-int-com-1/public/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the woocommerce-eu-vat-number domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/storm/sites/dev-imca-int-com-1/public/wp-includes/functions.php on line 6114
Emergency Lithium battery failed catastrophically in a diving bell - DEV imca
Skip to content

Emergency Lithium battery failed catastrophically in a diving bell

What happened?

During regular planned maintenance, a 24V DC emergency Lithium battery pack in a diving bell activated and failed catastrophically causing an explosion and small fire.  There were no injuries;  the bell was unoccupied at the time.  The incident occurred when a check valve on each of the Bell Emergency Battery Pack Pods was changed out for a more widely available type.

Crucially, the original valves were only threaded on one side with a male thread whereas the replacement type had the same male thread at each end.  A second thread on the new valve was not required as it does not connect to anything. This identical second thread introduced the potential for the new valves to be fitted in the wrong orientation.

After launch, the starboard bell status alarm for the 24V DC emergency battery pack activated. Initial visual inspection indicated no obvious fault. Upon recovery to the bell hanger the battery pack failed catastrophically, a loud noise was heard, and smoke and flames were emitted from the battery pack.

The battery pack pod had flooded through an incorrectly fitted check valve, causing the failure of the pod and subsequent fire.

Findings

  • There had been no Management of Change (MoC) process conducted and there had been no technical consideration of any new potential risks;
  • Valves with identical connection points can easily be fitted in the wrong orientation;
  • The crew were unaware of the immediate required action to extinguish the resulting fire.

Actions

  • Review of similar Emergency Battery Pack pods to review the check valves fitted to ensure they cannot be fitted incorrectly. Check valves with male/male threads to be removed;
  • Ensure that a thorough and appropriately technical Management of Change (MoC) process is carried out when changing out dive related components and equipment;
  • Personnel involved should ensure that they have a thorough understanding of the most appropriate immediate actions in the event of a Lithium type battery fire.

Safety Event

Published: 25 August 2020
Download: IMCA SF 25/20

Relevant life-saving rules:
IMCA Safety Flashes
Submit a Report

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding safetyreports@imca-int.com to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.

IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.

IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.