Partial pressure of oxygen (PPO₂) getting low in bell
What happened?
During saturation diving at approximately 147 msw, the diving supervisor noticed that Partial Pressure of Oxygen (PPOâ‚‚) was getting low in the diving bell. The supervisor instructed the bell man to inject some Oxygen into the bell. The bellman opened the main valve which charges a smaller bottle (buffer tank) with oxygen. He then closed the main valve and opened the second valve which allows the dosage of Oxygen to enter the bell. A few minutes later, he observed that the main bottle was empty. He secured the valves and notified the supervisor. The supervisor began to purge the bell with saturation breathing mix and instructed the bellman to put on a built-in breathing system (BIBS) mask. A few minutes later, the supervisor instructed the diver to return to the bell, remove his helmet and put on a BIBS. The bell was recovered to the surface. Once brought to the surface, the entire oxygen set up was checked for leaks, and operational status. There were no issues found with the equipment.
Our members’ findings were:
- Bell Oâ‚‚ make-up was routinely performed by Bell divers;
- The oxygen panel was inconveniently located behind the diver #2 umbilical;
- The panel was capable of opening both valves at once, allowing the buffer bottle to be introduced into the bell, and into the main Oâ‚‚ supply.
What actions were taken? What lessons were learned?
- Bell Oâ‚‚ make up performed by life support technician (LST) by flushing with premix instead of bell divers adding Oâ‚‚;
- Tubing was added to redirect Bell Oâ‚‚ to near the saturation bell scrubber fan;
- The oxygen panel was moved 45cm from the old position, re-installed and the divers were given instruction on its operation;
- The new valve configuration – a sliding mechanism and the tight tolerance if the valve is opened – will remove the likelihood that both valves could be open at the same time;
- The buffer tank was changed from a single penetration to a double penetration, with valves top and bottom in lieu of a single in/out valve.
Members may wish to refer to:
Safety Event
Published: 28 May 2019
Download: /home/storm/sites/dev-imca-int-com-1/public/wp-content/themes/imca-website-2020/single-safety-events.php on line 55
">
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding safetyreports@imca-int.com to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.